- % This program solves the swing equation of a one-machine system
- % when subjected to a three-phase fault with subsequent clearance
- % of the fault.
- %
- % Copyright (c) 1998 H. Saadat
- %
- function swingrk4(Pm, E, V, X1, X2, X3, H, f, tc, tf, Dt)
- %global Pm f H E V X1 X2 X3
- if exist('Pm') ~= 1
- Pm = input('Generator output power in p.u. Pm = '); else, end
- if exist('E') ~= 1
- E = input('Generator e.m.f. in p.u. E = '); else, end
- if exist('V') ~= 1
- V = input('Infinite bus-bar voltage in p.u. V = '); else, end
- if exist('X1') ~= 1
- X1 = input('Reactance before Fault in p.u. X1 = '); else, end
- if exist('X2') ~= 1
- X2 = input('Reactance during Fault X2 = '); else, end
- if exist('X3') ~= 1
- X3 = input('Reactance after Fault X3 = '); else, end
- if exist('H') ~= 1
- H = input('Generator Inertia constant in sec. H = '); else, end
- if exist('f') ~= 1
- f = input('System frequency in Hz f = '); else, end
- if exist('tc') ~= 1
- tc = input('Clearing time of fault in sec tc = '); else, end
- if exist('tf') ~= 1
- tf = input('Final time for swing equation in sec tf = '); else, end
- Pe1max = E*V/X1; Pe2max=E*V/X2; Pe3max=E*V/X3;
- clear t x delta
- d0 =asin(Pm/Pe1max);
- t0 = 0;
- x0 = [d0; 0];
- tol=0.001;
- %[t1,xf]=ode45('pfpower', t0, tc, x0, tol); % During fault solution (use with MATLAB 4)
- tspan = [t0; tc]; % use with MATLAB 5
- [t1,xf]=ode45('pfpower', tspan, x0); % During fault solution (use with MATLAB 5)
- x0c =xf(length(xf), :);
- %[t2,xc] =ode45('afpower', tc, tf, x0c, tol); % After fault solution (use with MATLAB 4)
- tspan = [tc, tf]; % use with MATLAB 5
- [t2,xc] =ode45('afpower', tspan, x0c); % After fault solution (use with MATLAB 5)
- t =[t1; t2]; x = [xf; xc];
- delta = 180/pi*x(:,1);
- clc
- fprintf('nFault is cleared at %4.3f Sec. n', tc)
- head=[' '
- ' time delta Dw '
- ' s degrees rad/s'
- ' '];
- disp(head)
- disp([t, delta, x(:, 2)])
- h=figure; figure(h)
- plot(t, delta), grid
- title(['One-machine system swing curve. Fault cleared at ', num2str(tc),'s'])
- xlabel('t, sec'), ylabel('Delta, degree')
- cctime(Pm, E, V, X1, X2, X3, H, f) % Obtains the critical clearing time