- E000-E049 : call failures
- E000 : Call successful
- E001 : Busy signal detected
- E002 : No carrier detected
- E003 : No answer from remote
- E004 : No local dialtone
- E005 : Invalid dialing command
- E006 : Unknown problem
- E007 : Carrier established, but Phase A failure
- E008 : Data connection established (wanted fax)
- E009 : Glare - RING detected
- E010 : Blacklisted by modem
- E011 : Ringback detected, no answer without CED
- E012 : Ring detected without successful handshake
- E050-E099 : non Class-specific fax protocol failures
- E050 : Missing EOL after 5 seconds
- E051 : Procedure interrupt received, job terminated
- E052 : Write error to TIFF file
- E100-E199 : Class 1-specific protocol failure
- E100 : Failure to receive silence (synchronization failure).
- E101 : Failure to raise V.21 transmission carrier.
- E102 : No sender protocol (T.30 T1 timeout)
- E103 : RSPREC error/got DCN (sender abort)
- E104 : RSPREC invalid response received
- E105 : Failure to train modems
- E106 : RSPREC error/got EOT
- E107 : Can not continue after DIS/DTC
- E108 : COMREC received DCN (sender abort)
- E109 : No response to RNR repeated 3 times.
- E110 : COMREC invalid response received
- E111 : V.21 signal reception timeout; expected page possibly not received in full
- E112 : Failed to properly detect high-speed data carrier.
- E113 : Received invalid CTC signal in V.34-Fax.
- E114 : Failed to properly open V.34 primary channel.
- E115 : Received premature V.34 termination.
- E116 : Failed to properly open V.34 control channel.
- E117 : COMREC invalid response to repeated PPR received
- E118 : T.30 T2 timeout, expected signal not received
- E119 : COMREC invalid partial-page signal received
- E120 : Cannot synchronize ECM frame reception.
- E121 : ECM page received containing no image data.
- E122 : Remote has no T.4 receiver capability
- E123 : DTC received when expecting DIS (not supported)
- E124 : COMREC error in transmit Phase B/got DCN
- E125 : COMREC invalid command received/no DIS or DTC
- E126 : No receiver protocol (T.30 T1 timeout)
- E127 : Stop and wait failure (modem on hook)
- E128 : Remote fax disconnected prematurely
- E129 : Procedure interrupt (operator intervention)
- E130 : Unable to transmit page (giving up after RTN)
- E131 : Unable to transmit page (giving up after 3 attempts)
- E132 : Unable to transmit page (NAK at all possible signalling rates)
- E133 : Unable to transmit page (NAK with operator intervention)
- E134 : Fax protocol error (unknown frame received)
- E135 : Fax protocol error (command repeated 3 times)
- E136 : DIS/DTC received 3 times; DCS not recognized
- E137 : Failure to train remote modem at 2400 bps or minimum speed
- E138 : Receiver flow control exceeded timer.
- E139 : No response to RR repeated 3 times.
- E140 : COMREC invalid response received to RR.
- E141 : No response to CTC repeated 3 times.
- E142 : COMREC invalid response received to CTC.
- E143 : Failure to transmit clean ECM image data.
- E144 : No response to EOR repeated 3 times.
- E145 : COMREC invalid response received to EOR.
- E146 : COMREC invalid response received to PPS.
- E147 : No response to PPS repeated 3 times.
- E148 : Unable to establish message carrier
- E149 : Unspecified Transmit Phase C error
- E150 : No response to MPS repeated 3 tries
- E151 : No response to EOP repeated 3 tries
- E152 : No response to EOM repeated 3 tries
- E153 : No response to PPM repeated 3 tries
- E154 : Timeout waiting for Phase C carrier drop.
- E155 : PPM received with no image data. To continue risks receipt confirmation.
- E200-E299 : Class 2-specific protocol failure
- E200 : Unable to request polling operation (modem may not support polling)
- E201 : Unable to setup polling identifer (modem command failed)
- E202 : Unable to setup selective polling address (modem command failed)
- E203 : Unable to setup polling password (modem command failed)
- E204 : Unable to send password (modem command failed)
- E205 : Unable to send subaddress (modem command failed)
- E206 : Unable to restrict minimum transmit speed to %s (modem command failed)
- E207 : Unable to setup session parameters prior to call (modem command failed)
- E208 : Unable to set session parameters
- E209 :
- E210 : Unknown hangup code
- E211 : Normal and proper end of connection
- E212 : Ring detect without successful handshake
- E213 : Call aborted, from +FK or <CAN>
- E214 : No loop current
- E215 : Ringback detected, no answer (timeout)
- E216 : Ringback detected, no answer without CED
- E217 : Unspecified Phase A error
- E218 : No answer (T.30 T1 timeout)
- E219 : Unspecified Transmit Phase B error
- E220 : Remote cannot be polled
- E221 : COMREC error in transmit Phase B/got DCN
- E222 : COMREC invalid command received/no DIS or DTC
- E223 : RSPREC error/got DCN
- E224 : DCS sent 3 times without response
- E225 : DIS/DTC received 3 times; DCS not recognized
- E226 : Failure to train at 2400 bps or +FMINSP value
- E227 : RSPREC invalid response received
- E228 : Unspecified Transmit Phase C error
- E229 : Unspecified Image format error
- E230 : Image conversion error
- E231 : DTE to DCE data underflow
- E232 : Unrecognized Transparent data command
- E233 : Image error, line length wrong
- E234 : Image error, page length wrong
- E235 : Image error, wrong compression code
- E236 : Unspecified Transmit Phase D error, including +FPHCTO timeout between data and +FET command
- E237 : RSPREC error/got DCN
- E238 : No response to MPS repeated 3 times
- E239 : Invalid response to MPS
- E240 : No response to EOP repeated 3 times
- E241 : Invalid response to EOP
- E242 : No response to EOM repeated 3 times
- E243 : Invalid response to EOM
- E244 : Unable to continue after PIN or PIP
- E245 : Unspecified Receive Phase B error
- E246 : RSPREC error/got DCN
- E247 : COMREC error
- E248 : T.30 T2 timeout, expected page not received
- E249 : T.30 T1 timeout after EOM received
- E250 : Unspecified Phase C error, including too much delay between TCF and +FDR command
- E251 : Missing EOL after 5 seconds (section 3.2/T.4)
- E252 : DCE to DTE buffer overflow
- E253 : Bad CRC or frame (ECM or BFT modes)
- E254 : Unspecified Phase D error
- E255 : RSPREC invalid response received
- E256 : COMREC invalid response received
- E257 : Unable to continue after PIN or PIP, no PRI-Q
- E258 : Command or signal 10 sec. timeout
- E259 : Cannot send: +FMINSP > remote's +FDIS(BR) code
- E260 : Cannot send: remote is V.29 only, local DCE constrained to 2400 or 4800 bps
- E261 : Remote station cannot receive (DIS bit 10)
- E262 : +FK aborted or <CAN> aborted
- E263 : +Format conversion error in +FDT=DF,VR, WD,LN Incompatible and inconvertable data format
- E264 : Remote cannot receive
- E265 : After +FDR, DCE waited more than 30 seconds for XON from DTE after XOFF from DTE
- E266 : In Polling Phase B, remote cannot be polled
- E267-279 (currently unused)
- E280 : Procedure interrupt (operator intervention)
- E281 : Unable to transmit page (giving up after RTN)
- E282 : Unable to transmit page (giving up after 3 attempts)
- E283 : Unable to transmit page (NAK at all possible signalling rates)
- E284 : Unable to transmit page (NAK with operator intervention)
- E285 : Modem protocol error (unknown post-page response)
- E286 : Batching protocol error
- E287 : Communication failure during Phase B/C
- E288 : Communication failure during Phase B/C (modem protocol botch)
- E300-E399 : Non-T.30 client or server failure
- E301 : Receive aborted due to operator intervention
- E302 : Problem reading document directory
- E303 : Internal botch; %s post-page handling string "%s"
- E304 : Maximum receive page count exceeded, call terminated
- E305 : Could not fork for scripted configuration.
- E306 : Bad exit status %#o for '%s'
- E307 : Could not open a pipe for scripted configuration.
- E308 : ANSWER: CALL REJECTED
- E309 : ANSWER: Call deduced as %s, but told to answer as %s; call ignored
- E310 : External getty use is not permitted {E310}
- E311 : %s: could not create
- E312 : "%s: can not fork: %s
- E313 : ERROR: Unknown status
- E314 : Can not open document file %s
- E315 : Can not set directory %u in document file %s
- E316 : Error reading directory %u in document file %s
- E317 : Too many pages in submission; max %u
- E318 : Unable to lock shared document file
- E319 : Unable to open shared document file
- E320 : Unable to create document file
- E321 : Converted document is not valid TIFF
- E322 : Could not reopen converted document to verify format
- E323 : Job contains no documents
- E324 : Modem does not support polling
- E325 : Kill time expired
- E326 : Invalid or corrupted job description file
- E327 : REJECT: Unable to convert dial string to canonical format
- E328 : REJECT: Requested modem %s is not registered
- E329 : REJECT: No work found in job file
- E330 : REJECT: Page width (%u) appears invalid
- E331 : REJECT: Job expiration time (%u) appears invalid
- E332 : REJECT: Time-to-send (%u) appears invalid
- E333 : REJECT: Too many attempts to dial
- E334 : REJECT: Too many attempts to transmit: %u, max %u
- E335 : REJECT: Too many pages in submission: %u, max %u
- E336 : REJECT: Modem is configured as exempt from accepting jobs
- E337 : Blocked by concurrent calls
- E338 : Delayed by time-of-day restrictions
- E339 : Delayed by outbound call staggering
- E340 : Could not fork to prepare job for transmission
- E341 : Could not fork to start job transmission
- E342 : Delayed by prior call
- E343 : Send program terminated abnormally; unable to exec %s
- E344 : Job interrupted by user
- E345 : Job aborted by request
- E400-E499 : job/modem incompatibility
- E400 : Modem does not support negotiated signalling rate
- E401 : Modem does not support negotiated min scanline time
- E402 : Document is not in a Group 3 or Group 4 compatible format (compression %u)
- E403 : Document was encoded with 2DMMR, but client does not support this data format
- E404 : Document was encoded with 2DMMR, but modem does not support this data format
- E405 : Document was encoded with 2DMMR, but ECM is not being used.
- E406 : Document was encoded with 2DMR, but client does not support this data format
- E407 : Document was encoded with 2DMR, but modem does not support this data format
- E408 : Hyperfine resolution document is not supported by client, image resolution %g x %g lines/mm
- E409 : Hyperfine resolution document is not supported by modem, image resolution %g x %g lines/mm
- E410 : Superfine resolution document is not supported by client, image resolution %g lines/mm
- E411 : Superfine resolution document is not supported by modem, image resolution %g lines/mm
- E412 : 300x300 resolution document is not supported by client, image resolution %g lines/mm
- E413 : 300x300 resolution document is not supported by modem, image resolution %g lines/mm
- E414 : High resolution document is not supported by client, image resolution %g lines/mm
- E415 : High resolution document is not supported by modem, image resolution %g lines/mm
- E416 : Client does not support document page width, max remote page width %g pixels, image width %lu pixels
- E417 : Modem does not support document page width, max page width %g pixels, image width %lu pixels
- E418 : Client does not support document page length, max remote page length %d mm, image length %lu rows (%.2f mm)
- E419 : Modem does not support document page length, max page length %s mm, image length %lu rows (%.2f mm)
- E500-E599 : paging failures
- E500 : No initial ID response from paging central
- E501 : Login failed multiple times
- E502 : Protocol failure: %s from paging central
- E503 : Protocol failure: %s waiting for go-ahead message
- E504 : Message block not acknowledged by paging central after multiple tries
- E505 : Message block transmit failed paging central rejected it
- E506 : Protocol failure: paging central responded to message block transmit with forced disconnect
- E507 : Protocol failure: %s to message block transmit
- E508 : Paging central rejected content; check PIN
- E509 : Protocol failure: timeout waiting for transaction ACK/NAK from paging central