att-dataport
上传用户:weiyuanprp
上传日期:2020-05-20
资源大小:1169k
文件大小:3k
源码类别:

传真(Fax)编程

开发平台:

C/C++

  1. # $Id: att-dataport,v 1.1.1.1 2005/11/11 21:32:01 faxguy Exp $
  2. #
  3. # HylaFAX Facsimile Software
  4. #
  5. # Copyright (c) 1990-1996 Sam Leffler
  6. # Copyright (c) 1991-1996 Silicon Graphics, Inc.
  7. # HylaFAX is a trademark of Silicon Graphics, Inc.
  8. # Permission to use, copy, modify, distribute, and sell this software and 
  9. # its documentation for any purpose is hereby granted without fee, provided
  10. # that (i) the above copyright notices and this permission notice appear in
  11. # all copies of the software and related documentation, and (ii) the names of
  12. # Sam Leffler and Silicon Graphics may not be used in any advertising or
  13. # publicity relating to the software without the specific, prior written
  14. # permission of Sam Leffler and Silicon Graphics.
  15. # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, 
  16. # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY 
  17. # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
  18. # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
  19. # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
  20. # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
  21. # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF 
  22. # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE 
  23. # OF THIS SOFTWARE.
  24. #
  25. #
  26. # Configuration for using the Class 1 command interface with
  27. # an AT&T DataPort 14.4 modem.  Firmware version 122 (ati1)
  28. # or newer.
  29. #
  30. # Hardware flow control is used by default.
  31. #
  32. # Note that due to a bug in the 1.22 firmware the FCS bytes in the HDLC
  33. # frames are NOT returned to the host.  This is fixed in versions 1.33
  34. # and later.  To deal with this problem, early firmware revs should be
  35. # sure to have Class1FrameOverhead set to 2 instead of the normal 4.
  36. #
  37. # CONFIG:CLASS1:144:.*:.*: Manufacturer='AT&T' Model=Dataport
  38. #
  39. # BEGIN-SERVER
  40. # END-SERVER
  41. #
  42. # Modem-related stuff: should reflect modem command interface
  43. # and hardware connection/cabling (e.g. flow control).
  44. #
  45. ModemType: Class1 # use class 1 interface
  46. ModemRate: 19200
  47. ModemFlowControl: rtscts # default
  48. #
  49. ModemHardFlowCmd: AT&R0D1Q3 # use RTS/CTS and enable RS232 handling
  50. ModemSoftFlowCmd: AT&R1D0Q1 # use RTS/CTS and enable RS232 handling
  51. ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
  52. ModemSetupDCDCmd: AT&C1 # setup so DCD follows carrier
  53. ModemSetupAACmd: AT+FAA=0 # disable in case of Class 2 support
  54. #
  55. ModemMfrQueryCmd: !AT&T
  56. ModemModelQueryCmd: !DataPort
  57. ModemRevQueryCmd: ATI19
  58. #
  59. # NB: this works around a bug in the 1.22 firmware; it is fixed
  60. # in versions 1.33 and later in which case you can remove this
  61. # line and use the default value of 4 (though leaving it as 2
  62. # won't harm anything).
  63. #
  64. Class1FrameOverhead: 2 # 1.22 firmware does not include FCS
  65. #
  66. # The modem returns "OK" when there is a timeout before carrier is
  67. # established.  This is treated as "NO CARRIER" by faxd.  Thus we
  68. # need to up the NoCarrierRetrys parameter to avoid having the server
  69. # reject jobs prematurely.
  70. #
  71. NoCarrierRetrys: 3 # retry 3 times on no carrier
  72. #
  73. PagerSetupCmds: ATS41=10%B300 # use V.21 at 300 bps