att-dataport
上传用户:weiyuanprp
上传日期:2020-05-20
资源大小:1169k
文件大小:3k
- # $Id: att-dataport,v 1.1.1.1 2005/11/11 21:32:01 faxguy Exp $
- #
- # HylaFAX Facsimile Software
- #
- # Copyright (c) 1990-1996 Sam Leffler
- # Copyright (c) 1991-1996 Silicon Graphics, Inc.
- # HylaFAX is a trademark of Silicon Graphics, Inc.
- #
- # Permission to use, copy, modify, distribute, and sell this software and
- # its documentation for any purpose is hereby granted without fee, provided
- # that (i) the above copyright notices and this permission notice appear in
- # all copies of the software and related documentation, and (ii) the names of
- # Sam Leffler and Silicon Graphics may not be used in any advertising or
- # publicity relating to the software without the specific, prior written
- # permission of Sam Leffler and Silicon Graphics.
- #
- # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
- # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
- # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
- #
- # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
- # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
- # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
- # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
- # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
- # OF THIS SOFTWARE.
- #
- #
- # Configuration for using the Class 1 command interface with
- # an AT&T DataPort 14.4 modem. Firmware version 122 (ati1)
- # or newer.
- #
- # Hardware flow control is used by default.
- #
- # Note that due to a bug in the 1.22 firmware the FCS bytes in the HDLC
- # frames are NOT returned to the host. This is fixed in versions 1.33
- # and later. To deal with this problem, early firmware revs should be
- # sure to have Class1FrameOverhead set to 2 instead of the normal 4.
- #
- # CONFIG:CLASS1:144:.*:.*: Manufacturer='AT&T' Model=Dataport
- #
- # BEGIN-SERVER
- # END-SERVER
- #
- # Modem-related stuff: should reflect modem command interface
- # and hardware connection/cabling (e.g. flow control).
- #
- ModemType: Class1 # use class 1 interface
- ModemRate: 19200
- ModemFlowControl: rtscts # default
- #
- ModemHardFlowCmd: AT&R0D1Q3 # use RTS/CTS and enable RS232 handling
- ModemSoftFlowCmd: AT&R1D0Q1 # use RTS/CTS and enable RS232 handling
- ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
- ModemSetupDCDCmd: AT&C1 # setup so DCD follows carrier
- ModemSetupAACmd: AT+FAA=0 # disable in case of Class 2 support
- #
- ModemMfrQueryCmd: !AT&T
- ModemModelQueryCmd: !DataPort
- ModemRevQueryCmd: ATI19
- #
- # NB: this works around a bug in the 1.22 firmware; it is fixed
- # in versions 1.33 and later in which case you can remove this
- # line and use the default value of 4 (though leaving it as 2
- # won't harm anything).
- #
- Class1FrameOverhead: 2 # 1.22 firmware does not include FCS
- #
- # The modem returns "OK" when there is a timeout before carrier is
- # established. This is treated as "NO CARRIER" by faxd. Thus we
- # need to up the NoCarrierRetrys parameter to avoid having the server
- # reject jobs prematurely.
- #
- NoCarrierRetrys: 3 # retry 3 times on no carrier
- #
- PagerSetupCmds: ATS41=10%B300 # use V.21 at 300 bps