- # $Id: rockwell-k56,v 1.1.1.1 2005/11/11 21:32:01 faxguy Exp $
- #
- # HylaFAX Facsimile Software
- #
- # Copyright (c) 1990-1996 Sam Leffler
- # Copyright (c) 1991-1996 Silicon Graphics, Inc.
- # HylaFAX is a trademark of Silicon Graphics, Inc.
- #
- # Permission to use, copy, modify, distribute, and sell this software and
- # its documentation for any purpose is hereby granted without fee, provided
- # that (i) the above copyright notices and this permission notice appear in
- # all copies of the software and related documentation, and (ii) the names of
- # Sam Leffler and Silicon Graphics may not be used in any advertising or
- # publicity relating to the software without the specific, prior written
- # permission of Sam Leffler and Silicon Graphics.
- #
- # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
- # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
- # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
- #
- # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
- # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
- # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
- # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
- # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
- # OF THIS SOFTWARE.
- #
- #
- # Configuration for a Rockwell AC/K56-based Class 2 modem.
- # based upon work of Mark J. Bailey, Jonathan Mau and Glenn Burkhardt.
- # Multitech MT5600ZDX
- # Diamond Multimedia SupraExpress 56e PRO
- # Zoom Telephonics 56Kx
- # (and others)
- #
- # This configuration file sets up the modem to run at 38.4 for
- # sending and for receiving. XON/XOFF is used for flow control
- # which also works for data connections. Adaptive answer support
- # is reliable, but to use it you must also enable ModemWaitForConnect
- # to force the server to skip intermediate status messages and
- # wait for the "CONNECT" message.
- #
- # CONFIG: CLASS2: Rockwell-MultiModemZDX*-*
- # CONFIG: CLASS2: ROCKWELL-AC/K56*-*
- # CONFIG: CLASS2: CONEXANT-AC/K56*-*
- # CONFIG: CLASS2: CONEXANT-V90-*
- #
- # BEGIN-SERVER
- # END-SERVER
- #
- # Modem-related stuff: should reflect modem command interface
- # and hardware connection/cabling (e.g. flow control).
- #
- ModemType: Class2 # use class 2 interface
- ModemRate: 19200
- ModemFlowControl: xonxoff # default
- ModemWaitForConnect: yes # wait for CONNECT on answer
- #
- #ModemResetCmds: AT&F2 # what you want for a Supra
- ModemNoFlowCmd: AT&K # disable flow control cmd
- ModemHardFlowCmd: AT&K3 # hardware flow control cmd
- ModemSoftFlowCmd: AT&K4 # software flow control cmd
- ModemSetupDTRCmd: AT&D3 # DTR off causes modem to reset
- ModemSetupDCDCmd: AT&C1 # DCD follows carrier
- ModemSetupAACmd: AT+FCLASS=0;+FAA=1 # enable in class 0
- #
- ModemSendFillOrder: LSB2MSB # as expected
- ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
- Class2RecvDataTrigger: "