rockwell-rc
上传用户:weiyuanprp
上传日期:2020-05-20
资源大小:1169k
文件大小:3k
源码类别:

传真(Fax)编程

开发平台:

C/C++

  1. # $Id: rockwell-rc,v 1.1.1.1 2005/11/11 21:32:01 faxguy Exp $
  2. #
  3. # HylaFAX Facsimile Software
  4. #
  5. # Copyright (c) 1990-1996 Sam Leffler
  6. # Copyright (c) 1991-1996 Silicon Graphics, Inc.
  7. # HylaFAX is a trademark of Silicon Graphics, Inc.
  8. # Permission to use, copy, modify, distribute, and sell this software and 
  9. # its documentation for any purpose is hereby granted without fee, provided
  10. # that (i) the above copyright notices and this permission notice appear in
  11. # all copies of the software and related documentation, and (ii) the names of
  12. # Sam Leffler and Silicon Graphics may not be used in any advertising or
  13. # publicity relating to the software without the specific, prior written
  14. # permission of Sam Leffler and Silicon Graphics.
  15. # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, 
  16. # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY 
  17. # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
  18. # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
  19. # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
  20. # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
  21. # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF 
  22. # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE 
  23. # OF THIS SOFTWARE.
  24. #
  25. #
  26. # Configuration for a Rockwell-based modem not otherwise handled by
  27. # another prototype configuration file.  This file assumes the modem
  28. # is compatible with the Rc144AC, RC96AC or RC144DP.
  29. #
  30. # This configuration file sets up the modem to run at 38.4 with
  31. # RTS/CTS flow control used by default.  XON/XOFF is automatically
  32. # enabled for fax recv.  Beware of modems that also lock sending
  33. # to 19.2; add ModemSendBeginCmd: "<19200>" if this is required.
  34. # Also beware that the adaptive-answer facility, when supported,
  35. # is often unreliable.
  36. #
  37. # CONFIG: CLASS2: ROCKWELL*-*
  38. #
  39. # BEGIN-SERVER
  40. # END-SERVER
  41. #
  42. # Modem-related stuff: should reflect modem command interface
  43. # and hardware connection/cabling (e.g. flow control).
  44. #
  45. ModemType: Class2 # use class 2 interface
  46. ModemRate: 19200
  47. ModemFlowControl: rtscts # default
  48. #
  49. #ModemResetCmds: AT&F2 # what you want for a Supra
  50. ModemNoFlowCmd: AT&K # disable flow control cmd
  51. ModemHardFlowCmd: AT&K3 # hardware flow control cmd
  52. ModemSoftFlowCmd: AT&K4 # software flow control cmd
  53. ModemSetupDTRCmd: AT&D3 # DTR off causes modem to reset
  54. #ModemSetupDTRCmd: AT&D2S25=1S38=0 # Dynalink 1414VE needs this
  55. ModemSetupDCDCmd: AT&C1 # DCD follows carrier
  56. ModemSetupAACmd: AT+FAA=1+FCLASS=0 # enable in current class
  57. #
  58. ModemSendFillOrder: LSB2MSB # as expected
  59. ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
  60. #
  61. ModemAnswerFaxBeginCmd: "<19200><xon>" # modem switches on fax receive
  62. #
  63. # Caller ID configuration setup for Supra.
  64. #
  65. #QualifyCID: etc/cid # CID access control list file
  66. #CallIDPattern: "NMBR = " # pattern string for phone number info
  67. #CallIDPattern: "NAME = " # pattern string for identity info