rockwell-rc
上传用户:weiyuanprp
上传日期:2020-05-20
资源大小:1169k
文件大小:3k
- # $Id: rockwell-rc,v 1.1.1.1 2005/11/11 21:32:01 faxguy Exp $
- #
- # HylaFAX Facsimile Software
- #
- # Copyright (c) 1990-1996 Sam Leffler
- # Copyright (c) 1991-1996 Silicon Graphics, Inc.
- # HylaFAX is a trademark of Silicon Graphics, Inc.
- #
- # Permission to use, copy, modify, distribute, and sell this software and
- # its documentation for any purpose is hereby granted without fee, provided
- # that (i) the above copyright notices and this permission notice appear in
- # all copies of the software and related documentation, and (ii) the names of
- # Sam Leffler and Silicon Graphics may not be used in any advertising or
- # publicity relating to the software without the specific, prior written
- # permission of Sam Leffler and Silicon Graphics.
- #
- # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
- # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
- # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
- #
- # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
- # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
- # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
- # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
- # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
- # OF THIS SOFTWARE.
- #
- #
- # Configuration for a Rockwell-based modem not otherwise handled by
- # another prototype configuration file. This file assumes the modem
- # is compatible with the Rc144AC, RC96AC or RC144DP.
- #
- # This configuration file sets up the modem to run at 38.4 with
- # RTS/CTS flow control used by default. XON/XOFF is automatically
- # enabled for fax recv. Beware of modems that also lock sending
- # to 19.2; add ModemSendBeginCmd: "<19200>" if this is required.
- # Also beware that the adaptive-answer facility, when supported,
- # is often unreliable.
- #
- # CONFIG: CLASS2: ROCKWELL*-*
- #
- # BEGIN-SERVER
- # END-SERVER
- #
- # Modem-related stuff: should reflect modem command interface
- # and hardware connection/cabling (e.g. flow control).
- #
- ModemType: Class2 # use class 2 interface
- ModemRate: 19200
- ModemFlowControl: rtscts # default
- #
- #ModemResetCmds: AT&F2 # what you want for a Supra
- ModemNoFlowCmd: AT&K # disable flow control cmd
- ModemHardFlowCmd: AT&K3 # hardware flow control cmd
- ModemSoftFlowCmd: AT&K4 # software flow control cmd
- ModemSetupDTRCmd: AT&D3 # DTR off causes modem to reset
- #ModemSetupDTRCmd: AT&D2S25=1S38=0 # Dynalink 1414VE needs this
- ModemSetupDCDCmd: AT&C1 # DCD follows carrier
- ModemSetupAACmd: AT+FAA=1+FCLASS=0 # enable in current class
- #
- ModemSendFillOrder: LSB2MSB # as expected
- ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
- #
- ModemAnswerFaxBeginCmd: "<19200><xon>" # modem switches on fax receive
- #
- # Caller ID configuration setup for Supra.
- #
- #QualifyCID: etc/cid # CID access control list file
- #CallIDPattern: "NMBR = " # pattern string for phone number info
- #CallIDPattern: "NAME = " # pattern string for identity info