att-dpexpress-2
上传用户:weiyuanprp
上传日期:2020-05-20
资源大小:1169k
文件大小:3k
- # $Id: att-dpexpress-2,v 1.1.1.1 2005/11/11 21:32:01 faxguy Exp $
- #
- # HylaFAX Facsimile Software
- #
- # Copyright (c) 1990-1996 Sam Leffler
- # Copyright (c) 1991-1996 Silicon Graphics, Inc.
- # HylaFAX is a trademark of Silicon Graphics, Inc.
- #
- # Permission to use, copy, modify, distribute, and sell this software and
- # its documentation for any purpose is hereby granted without fee, provided
- # that (i) the above copyright notices and this permission notice appear in
- # all copies of the software and related documentation, and (ii) the names of
- # Sam Leffler and Silicon Graphics may not be used in any advertising or
- # publicity relating to the software without the specific, prior written
- # permission of Sam Leffler and Silicon Graphics.
- #
- # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
- # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
- # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
- #
- # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
- # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
- # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
- # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
- # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
- # OF THIS SOFTWARE.
- #
- #
- # Configuration for using the Class 2 command interface with
- # an AT&T DataPort Express 14.4 modem. Model 3715-A1-202
- # Firmware version (ati1) FW Level 091394 Checksum 182050 V1.15.07 SA
- # or newer.
- #
- # Hardware flow control is used by default.
- #
- # CONFIG: CLASS2: AT?T*PARADYNE*-ROCKWELL*144DPI*
- #
- # BEGIN-SERVER
- # END-SERVER
- #
- # Modem-related stuff: should reflect modem command interface
- # and hardware connection/cabling (e.g. flow control).
- #
- ModemType: Class2 # use class 2 interface
- ModemRate: 19200 # set rate for DCE-DTE communication
- ModemFlowControl: rtscts # default
- #
- ModemHardFlowCmd: AT&R0D1Q3 # use RTS/CTS and enable RS232 handling
- ModemSoftFlowCmd: AT&R1D0Q1 # use RTS/CTS and enable RS232 handling
- ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
- ModemSetupDCDCmd: AT&C1 # setup so DCD follows carrier
- ModemSetupAACmd: AT+FAA=1 # enable adaptive-answer in Class 2
- #
- ModemRecvFillOrder: MSB2LSB # bit order of received facsimile
- ModemSendFillOrder: LSB2MSB # bit order modem expects for transmit
- #
- ModemDialCmd: ATDT%s # T for tone dialing
- #
- # Chip locks the line rate and switches to xon/xoff flow
- # control when receiving facsimile--we must follow suit.
- #
- ModemAnswerFaxBeginCmd: "<19200><xon>" # lock line rate & switch flow control
- #
- Class2RecvDataTrigger: "