rc144ac
上传用户:weiyuanprp
上传日期:2020-05-20
资源大小:1169k
文件大小:3k
源码类别:

传真(Fax)编程

开发平台:

C/C++

  1. # $Id: rc144ac,v 1.1.1.1 2005/11/11 21:32:01 faxguy Exp $
  2. #
  3. # HylaFAX Facsimile Software
  4. #
  5. # Copyright (c) 1990-1996 Sam Leffler
  6. # Copyright (c) 1991-1996 Silicon Graphics, Inc.
  7. # HylaFAX is a trademark of Silicon Graphics, Inc.
  8. # Permission to use, copy, modify, distribute, and sell this software and 
  9. # its documentation for any purpose is hereby granted without fee, provided
  10. # that (i) the above copyright notices and this permission notice appear in
  11. # all copies of the software and related documentation, and (ii) the names of
  12. # Sam Leffler and Silicon Graphics may not be used in any advertising or
  13. # publicity relating to the software without the specific, prior written
  14. # permission of Sam Leffler and Silicon Graphics.
  15. # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, 
  16. # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY 
  17. # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
  18. # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
  19. # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
  20. # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
  21. # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF 
  22. # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE 
  23. # OF THIS SOFTWARE.
  24. #
  25. #
  26. # Configuration for a Rockwell V.32AC Class 2 modem
  27. # (RC144AC, RC96AC or using RC144DP).
  28. #    Boca M1440E firmware V1.270 or newer
  29. #    Dallas Fax (throw it away!)
  30. #    Hayes Optima 24+Fax96 firmware TR00-J260-001 XXX or newer
  31. #    SupraFAX v.32bis firmware V1.200-C or newer
  32. #    Twincom 144/DF firmware rev V1.200 or newer
  33. #    Dynalink 1414VE firmware rev ???
  34. # (and others)
  35. #
  36. # This configuration file sets up the modem to run at 38.4 with
  37. # RTS/CTS flow control used by default.  XON/XOFF is automatically
  38. # enabled for fax recv.  Beware of modems that also lock sending
  39. # to 19.2; add ModemSendBeginCmd: "<19200>" if this is required.
  40. # Also beware that the adaptive-answer facility, when supported,
  41. # is often unreliable.
  42. #
  43. # CONFIG: CLASS2: *-V.32AC-*
  44. #
  45. # BEGIN-SERVER
  46. # END-SERVER
  47. #
  48. # Modem-related stuff: should reflect modem command interface
  49. # and hardware connection/cabling (e.g. flow control).
  50. #
  51. ModemType: Class2 # use class 2 interface
  52. ModemRate: 19200
  53. ModemFlowControl: rtscts # default
  54. #
  55. #ModemResetCmds: AT&F2 # what you want for a Supra
  56. ModemNoFlowCmd: AT&K # disable flow control cmd
  57. ModemHardFlowCmd: AT&K3 # hardware flow control cmd
  58. ModemSoftFlowCmd: AT&K4 # software flow control cmd
  59. ModemSetupDTRCmd: AT&D3 # DTR off causes modem to reset
  60. #ModemSetupDTRCmd: AT&D2S25=1S38=0 # Dynalink 1414VE needs this
  61. ModemSetupDCDCmd: AT&C1 # DCD follows carrier
  62. ModemSetupAACmd: AT+FAA=1+FCLASS=0 # enable in current class
  63. #
  64. ModemSendFillOrder: LSB2MSB # as expected
  65. ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
  66. #
  67. ModemAnswerFaxBeginCmd: "<19200><xon>" # modem switches on fax receive
  68. #
  69. # Caller ID configuration setup for Supra.
  70. #
  71. #QualifyCID: etc/cid # CID access control list file
  72. #CallIDPattern: "NMBR = " # pattern string for phone number info
  73. #CallIDPattern: "NAME = " # pattern string for identity info