- # $Id: lucent-mt-10,v 1.6 2007/10/03 23:52:11 faxguy Exp $
- #
- # prototype config for MultiTech 5634-series modems using
- # the Lucent/Agere chipset supporting V.34-Fax.
- #
- # CONFIG:CLASS1.0:LT V.90 1.0 MT5634ZPX-PCI*:.*:.*: Manufacturer=MultiTech Model=MT5634ZPX-PCI
- # CONFIG:CLASS1.0:LT V.92 1.0 MT5634ZPX-PCI*:.*:.*: Manufacturer=MultiTech Model=MT5634ZPX-PCI-V92
- # CONFIG:CLASS1.0:LT V.90 1.0 MT5634ZBA*:.*:.*: Manufacturer=MultiTech Model=MT5634ZBA
- # CONFIG:CLASS1.0:LT V.92 1.0 MT5634ZBA*:.*:.*: Manufacturer=MultiTech Model=MT5634ZBA
- # CONFIG:CLASS1.0:LT V.90 1.0 ISI5634PCI*:.*:.*: Manufacturer=MultiTech Model=ISI5634PCI
- # CONFIG:CLASS1.0:LT V.92 1.0 ISI5634PCI*:.*:.*: Manufacturer=MultiTech Model=ISI5634PCI
- # CONFIG:CLASS1.0:LT V.92 1.0 MT5634SMI*:.*:.*: Manufacturer=MultiTech Model=MT5634SMI
- #
- # BEGIN-SERVER
- # END-SERVER
- ModemType: Class1.0 # use this to supply a hint
- ModemRate: 57600 # must be at least as fast as the DCE-DCE communication
- ModemFlowControl: rtscts # many firmwares have broken software flow control
- ModemSetupDTRCmd: AT&D3 # hang up and reset on DTR drop
- Class1EnableV34Cmd: AT+F34=14,1,2 # 33600-2400 primary, 2400-1200 control
- Class1TMConnectDelay: 400 # counteract quick CONNECT response
- Class1HasRHConnectBug: yes # cope with +FRH=3 CONNECT errors
- # If your line supports Caller-ID, you may want to uncomment this...
- # ModemResetCmds: AT+VCID=1
- # CallIDPattern: "NMBR="
- # CallIDPattern: "NAME="
- # Or with the MT5634ZBA-DID you'll probably need something like...
- # ModemReadyCmds: AT*DS1*DD0*DF1*DN4 # enable DTMF-DID, wink-start, 4 digits
- # CallIDPattern: "DTMF" # format of AT*DF1
- # CallIDAnswerLength: 4 # four DTMF-DID digits then ATA
- # ModemResetCmds: AT*DP1 # to reverse the polarity