MibBrowser.properties
上传用户:aonuowh
上传日期:2021-05-23
资源大小:35390k
文件大小:43k
- #edited properties
- #Wed Apr 16 20:05:48 GMT+05:30 2003
- Load recently loaded Mibs at startup=
- Reading map file:=
- Helps to create a parser file that will Filter incoming Traps in the Trap Viewer.=
- USMUtils:encrypt:Null PointerException generating RawSecretKey:=
- Error generating Debug dump=
- VariableBindings Index out of Range=
- SNMP PDU (type unknown/unspecified=
- Show Augmented table or Original table=
- Invalid ColumnIndex:=
- Primary OID Table size :=
- Loading MIBs Failed:=
- MibsJDBCDialog=
- DefVal=
- Major=
- Wrong PrivPassword=
- Invalid PrivPassword=
- PrivPassword may be Wrong=
- Could not create ACM table=
- Target Port=
- Load MIB=
- The keyword 'REVISION' may be missing.=
- and module name=
- Import File=
- Error: Agent Returned a Non-Numeric Value=
- Time in seconds=
- AdventNet MibBrowser=
- Node syntax not OID type=
- Port=
- Restart=
- coldStart=
- Socket terminated=
- Select All=
- the parser file=
- Could not list the Directory=
- Enter the OID=value pair. If the received trapPDU contains=
- Invalid Non-Rep Number:=
- Enter ParserName=
- was missing since the previous fields quoted string was not ends with quotes.=
- Serious=
- View the not-accessible index=
- Discovery failed for address=
- Parent nodes did not match after=
- Error in getting Database Connection.Please check the Jdbc Parameters=
- Invalid OID String:=
- User Name=
- Snmp Decoder=
- TimeReceived=
- Error : No OID set in the index=
- Critical Level=
- IMPORTS failed:=
- Save?=
- Not connected to SAS server=
- Parse Error: Decoding uptime.=
- NormalSettings=
- Timeout:=
- Sending trap message to host=
- Time in weeks=
- AUTH_PRIV=
- PrivacyKey length cannot be greater than=
- Discovery failed for user=
- Exception: SnmpDataAndTime: Not a valid hour=
- Label for the Trap parser. This is used only for administration purposes and not for parsing=
- Error cloning syntax :=
- TrapViewer=
- Object ID=
- in mib=
- Exception occurred during Snmp Engine Boots serialization=
- UnLoad MIB=
- Exception closing socket=
- Loading option set to Compiled File.=
- and the current EngineID. Cannot Overwrite=
- Error in set request to=
- UnLoad All MIBs=
- Timeout=
- The keyword 'DESCRIPTION' or 'REFERENCE' may be missing.=
- A authorization failed error occurred.=
- Serious Level=
- Save MibBrowser Decoder Results=
- Agent name with portnumber already exists =
- Error: Error creating variable.=
- Load Debug File=
- Invalid SNMP Version for sending a v1 trap=
- Severity color ...=
- Invalid contextName=
- Username should be specified.=
- Agent=
- Unknown=
- SIZE=
- not same as reqd.=
- Invalid Hex Argument=
- Called for resolution using self.=
- Error : No such column exists=
- Invalid interval value:=
- Mib Settings=
- Invalid Timeout Parameter:=
- Clear Result Display=
- The open brace may be missing.=
- File contains Non SNMP Message(s).=
- Cannot set agent address in trap.=
- ACM table created=
- Class Not found=
- Parse Error : Expected Security param string=
- Status=
- All the Mibs already loaded will be unloaded.=
- Continuing without Internationalizing=
- Error in adding row=
- USMUtils:encrypt:No Such Padding :=
- Parse Error: Decoding message max size.=
- A not writable error occurred.=
- MsgID:=
- Writer version doesn't match reader version nContinuing anyway...=
- Delete Entry=
- Mibs has been loaded in Other modes.=
- SNMP Version: Version 2C=
- Load Options=
- Exception string is=
- threads did not stop in=
- Parse Auth: Incorrect VarBindList=
- Couldn't resolve these sequence constructs :=
- Exception:SnmpDataAndTime:The byte [] length should be either 8 or 11=
- A undo failed error occurred.=
- Parse Header: Incorrect Scoped data=
- About MibBrowser ...=
- Error: External Index for table not found=
- Current Level=
- One of these keyword 'SYNTAX' , 'WRITE-SYNTAX', 'ACCESS' , 'CREATION-REQUIRES' or 'DEFVAL' may be missing.=
- Adding TC Element=
- Node data printin...=
- Error creating SnmpIpAddress : invalid String arg.=
- OID LABEL=
- USMUtils:encrypt:Cipher not an instance of FeedbackCipher=
- create_v3_tables: interrupted=
- Type :=
- Error Details for the selected Mib is :=
- ReqID:=
- No remote IP address specified.=
- USMUtils:encrypt:Invalid Key Algorithm :=
- Enter the URL or filename for MIB file=
- Failed.=
- AugmentedTable=
- Error : Row index=
- Parse Error : Expected engine time=
- SNMP Get Bulk Request PDU=
- should contain one of these values :=
- Type=
- Timed out: no more retries to=
- Parse Header: Incorrect Context Id=
- Unable to create file=
- Set SNMP variable=
- Sent set request to=
- Only the base datatype and TEXTUAL-CONVENTIONs are allowed as syntax in the SEQUENCE construct. Invalid name (character comma) may present as syntax.=
- A wrong type error occurred.=
- USMUtils:encrypt:Key length :=
- v2c=
- ParserEditor=
- Parser name=
- Bar Graph=
- Database Parameters=
- Enter the file Name of MibModule=
- X-axis Scale (>300)=
- Delete the Selected Rows=
- Trying to set an invalid value=
- Log FileName=
- Write error:=
- subOID value should not exceed 4294967295=
- Header Name Change Editor=
- The file doesn't exists=
- RemotePort=
- SYNTAX :=
- Get SNMP variable=
- The value given has wrong type or length.=
- macroType=
- Parse Error : Expected engine boots=
- IMPORTS failed : import MIB=
- Receive error: Ignoring the Received message and starting receiver again=
- Expand the Tree=
- Unable to close the connection :=
- MIB loading failed:=
- Entity=
- There is no such variable name in this MIB.=
- File name:=
- of the=
- The keyword 'REFERENCE' or 'ASSIGNMENT (::=
- does not contain=
- USMUtils:encrypt:privProtocol should be CBC_DES=
- Error : Row count cannot be negative=
- User Defined Level=
- session.send: Unable to encode PDU=
- Exception: SnmpDataAndTime: Not a valid direction=
- mismatch !=
- session.send: error while sending=
- Exception running task:=
- DATA=
- Unable to get entry :=
- SAS server not connected=
- Client Call Timeout.=
- MIB Description=
- Please enter the Locale and Font for Internationalization=
- Graphing=
- Start=
- Copy=
- v1 =
- Parse Error: Wrong SNMP Version:=
- Save File As=
- delete the selected rows from the table=
- Exception in encoding :=
- Entry already exists for the TargetHost:=
- Parsing Levels=
- Specified node was not foundnPassed the end of MIB Tree=
- Discovery failed for user :=
- USMUserEntry : could not send a unsupportedSecLevels report PDU=
- Invalid SNMP Version Number=
- Minor=
- Authoritative Engine ID=
- Select any one of the entry from the table=
- Line Graph=
- Find MIB Node=
- Error : Security Model cannot be negative=
- Parse Error: Decoding message Flags.=
- IO error:=
- Loading MIB File=
- Using Textual Convention :=
- SNMP PDU Variable Bindings:=
- Invalid Instance string=
- Enterprise=
- Quoted string is expected.=
- v3Settings=
- Error: Request Timed Out=
- Error during setting Database Params:=
- Unable to insert entries :=
- Exception while setting properties for bean=
- Debug=
- MibBrowser Applet does not saven MibBrowser Debug Messages into files=
- Error in Database Params :=
- Ok=
- Cannot decode ASN Type:=
- Overwrite MIBs in Database.=
- Index :=
- StopPolling=
- Warning : OID Sub-Identifiers exceed 128=
- Exception in creating securityModel Entry=
- Community=
- Value should be entered in IndexEditor=
- Error : Column index=
- Connection not established=
- sequence ?=
- TrapList=
- An additional comma may present in the SEQUENCE construct.=
- No=
- The default value is not correct=
- Unloading MIB Failed:=
- Load Parser File=
- OK=
- null=
- some behaviour could be unexpected..=
- Unable to update entry :=
- UpTime:=
- A authorization failed error occurred.=
- This table contains the parser list information to be saved into=
- Syntax:=
- This variable is read only.=
- Invalid Binary String:=
- Errors In Parsing=
- Index:=
- Add=
- Major Error : wellKnownName mismatch. Report to support@adventnet.com with MIB file=
- GraphType=
- delete the selected rows from=
- Non-negative integer is expected.=
- JDBC Parameters=
- Page Size(Rows)=
- Cannot List Remote Files=
- Parse Error : unrecognized SNMP message=
- Reading Sequence=
- Error reading map:=
- Not-accessible Index=
- Browse Option is not supported with HTTP protocol. Enter the filename=
- Context ID=
- A wrong value error occurred.=
- Encoding Not Supported=
- File of type:=
- connection established:=
- Invalid Max-Rep Number:=
- Load MIB Module=
- Sent getbulk request to=
- Mib Loading Options=
- Error : OID not specified=
- Could not open description file=
- Prev=
- Not a valid minute=
- New parser=
- View MIB Description=
- Auth,noPriv=
- Retrieving imports object for=
- Send Error :=
- Searches for the specified node name in all the loaded modules=
- Expecting the left brace.=
- IO error resending to=
- Save V3 Settings to File=
- Overwrite existing compiled MIB files=
- A general failure occurred.=
- MibBrowser Settings=
- Error : No such column=
- Exception occurred :=
- VARIABLES=
- Could not create table :=
- Version=
- Custom=
- Mib database is not connected.=
- The DISPLAY-HINT or STATUS keyword may be missing.=
- Request failed:=
- Response message too large=
- Not a TableOID.=
- Enter the Font name, Style and Size for the font=
- Exception occurred during serialization=
- There is no such instance in this MIB.=
- Null value for OIDs or Vars=
- Trap Parser Name=
- Error in SyncSend :=
- Invalid oid construct in the OBJECT-TYPE construct.=
- Error in open :=
- USMUtils:encrypt:No Such Algorithm :=
- Max. Repetitions=
- Response message would have been too large.=
- Error: Security Exception connecting to remote host=
- Couldn't resolve these TC constructs :=
- Error: Invalid Context Name=
- Add a new row to the table=
- Decryption failed:=
- Show selected number of rows=
- Look in:=
- Error occurred while sending=
- Could not parse the file=
- Sequence List Count :=
- Parse Error: Decoding enterprise.=
- Load All MIBs=
- Invalid generic type for trap=
- No Trap or Notification Definitions found in the Mib.=
- Exception: SnmpDataAndTime: Not a valid date=
- Reading OID :=
- Clear=
- Load MIBs directly=
- Average over Interval?=
- Database not connected=
- Error: Agent Returned Empty Data=
- Load MIBs From Database=
- Critical=
- A wrong encoding error occurred.=
- Receive error: Aborting session receiver=
- Graph=
- DataBase Not Found=
- Title=
- Priv Password=
- Counter value=
- Enable Logging=
- Print=
- PDU=
- Not a valid hour=
- Select any of the entry in the table to modify=
- SNMP Table -=
- Loading MIB File =
- Unloading MibModule(s) Failed:=
- Agent-Port List=
- Unable to encode PDU.=
- Error getting OID:=
- Only numeric values allowed.Spaces are not allowed=
- Display=
- Error sending req for Traps=
- Enter an OID.=
- Invalid data for table :=
- Time in days=
- Node :=
- Edit=
- GetNext=
- There is no Browser available to view Help. Please install a browser to view the Help=
- Exception occurred while loadingtthe mibs:=
- Time Out=
- Context Name=
- Save=
- Decode=
- Flags=
- Given OID matches the filterSubTree=
- Incorrect no of OIDs and Vars=
- Exception occurred during serialization=
- View Trap Details=
- Sent get request to=
- Enter a value.=
- The MIB file may be corrupt or wrong=
- Polling Interval=
- Specified OID :=
- Error decoding variable=
- Network=
- The identifier Module name or TEXTUAL-CONVENTION should startwith uppercase letter.=
- Cannot have a SEQUENCE which=
- Get Next SNMP variable=
- Old Name=
- Normal=
- Error: Invalid Table OID:=
- could not create the ACM=
- Set Failed.=
- Security Exception connecting to remote host=
- Content vector is null=
- Show Polled Values?=
- Select any one entry from the table to set=
- Error in opening the file :=
- Please enter the Driver Name=
- Read in trap reference :=
- threads stopped out of=
- Parse Error: Decoding errindex.=
- Directories=
- ErrorString is=
- The byte [] length should be either 8 or 11=
- Multi-Var=
- Error: Invalid Version=
- MessageID=
- The error occurred at the line no:=
- Specifies the Domain value Corresponding to the trap. Usage of this domain field is application specific.=
- Specifies the Generic Type value of the Trap. The acceptable value range is 0-6=
- Print MibBrowser Results=
- Continuing Anyway=
- Description :=
- Agent Address=
- Dropping this trap=
- nIt may expecting one of the n1. The subOID value should be a number with value ranges==
- File not found=
- Error opening socket at applet host.=
- Error sending getbulk request to=
- Trap List=
- In the=
- Response PDU received from=
- Invalid option:=
- The value given has the wrong type or length.=
- Engine Time=
- The REFERENCE or SYNTAX keyword was missing.=
- Remote Port:=
- Error: IP address Not specified.=
- SNMP Version=
- usmStatsUnknownEngineIDs=
- Specifies the Severity value for this trap=
- Message=
- SNMP Get Request PDU=
- Get Bulk Options=
- is invalid=
- Print error:=
- Encoding=
- Size less than array limits.=
- Unable to create Connection: Database access error=
- Invalid Specific Type=
- Class=
- An inconsistent value error occurred.=
- DATA:=
- Lenient=
- Stop Polling The Table=
- A no creation error occurred.=
- Invalid protocol=
- Parse Auth: Incorrect ASN header=
- ContextEngineID=
- Couldn't find it=
- Not a valid direction=
- Error : Index cannot be negative=
- Read in trap name :=
- No Error.=
- Graphing on=
- Retries=
- LineGraphBean Error: cannot plot value.=
- spaceLeft=
- Displays the detailed description of the trap=
- Count of Imported Oids:=
- Parser Create Options=
- Error Index:=
- add a new row to the table=
- MibModule=
- Sending trap message for host=
- Number of Elements=
- Validate Broadcast Address=
- The keyword=
- Specifies the help url for this trap. The help button in the \"Event Details\" screen of the product will bring up this page=
- The OID:value already exists=
- Apply=
- Unable to remove the entry :=
- Bar=Graph=
- PDU received from=
- Error Indication in response:=
- Database=
- Cannot decode instance:=
- Error in closing output Stream :=
- Enter OID and Value fields=
- Data is null=
- Exception has occurred while writing=
- Security error creating SnmpIpAddress instance.=
- Parse Error : Expected auth string=
- Invalid SnmpPort Parameter:=
- usmStatsDecryptionErrors=
- Warning = Select an item from the TrapList=
- SnmpTable LineGraph=
- Some problem in decoding IPADDRESS defval:=
- Snmp_Version2c=
- Next=
- Reading traps. Count :=
- Cannot get Remote Files=
- Table OID=
- IO error sending PDU.=
- Object ID :=
- additional bytes=
- Error in shifting tableoid :=
- Show table rows of the previous page=
- Drivername=
- Domain=
- IOException occurred:=
- shown on the Trap Table.=
- The remaining=
- SNMP Version:=
- SyncSend request Failed:=
- Connection has been established=
- The identifier should startwith lowercase letter=
- Value is invalid=
- Severity Color=
- Info=
- Could not open file=
- No MIBs loaded=
- Parse Error : Unsupported security model=
- MibNode Description=
- Parse Version: Incorrect ASN header=
- Specifies the source Field value for the trap=
- SystemUpTime=
- column:=
- Back=
- Receive error=
- About=
- Community:=
- Category=
- Schedulers did not stop properly:=
- FileName not specified=
- Max Poll Duration(sec's.)=
- There is no such variable name in this mib.=
- Searching in module=
- Print Results...=
- The OID component value should be enclosed within brackets or the OID construct may not end with right brace.=
- Do you want to unload the MIBs?=
- Session Remote Host Unknown.=
- No OID Specified=
- Response from the agent had a non-zero errorIndex value :=
- Parser List=
- Exception while initializing security provider=
- Error in writing to error Stream :=
- A general failure occurred=
- File already exists.nDo you want to replace it?=
- For the table and row OBJECT-TYPE construct the ACCESS value should be 'not-accessible'. or=
- Error cloning in updateSyntax of MibNode :=
- Auth Password=
- Units=
- Stop=
- Found a link to an unresolved TC :=
- Path=
- Error=
- The keyword 'REFERENCE' or 'MODULE' may be missing=
- Match word=
- session.send : SecurityException while connecting to remote host:=
- One of these keyword 'REFERENCE' 'SUPPORTS', 'VARIATIONS' or ASSIGNMENT (::=
- Invalid contextID=
- Error : Column count cannot be negative=
- Cyclic TC=
- since Overwrite Compiled file is not selected.=
- Value=
- Description=
- Normal Level=
- Parse Error : Expected user name=
- Invalid OID label :=
- An inconsistent name error occurred.=
- IOException :=
- The identifier should not startswith number or special character.=
- Invalid Version Number=
- Help URL=
- Error: Illegal Argument(s)=
- Xval=
- Not a leaf node. OID:=
- Trap Viewer=
- Timed out : Resending=
- Starting Receiver on this session=
- Invalid cast:=
- Searches for the specified node name matching the word entered=
- Column inaccessible. Drop:=
- The keyword 'VARIABLES, DESCRIPTION, REFERENCE or ASSIGNMENT (::=
- Unable to remove the given entry :=
- Load/Save TrapParsers=
- ContextName=
- Unable to remove entry :=
- Save Results As...=
- File Name Invalid=
- Invalid OID format:=
- Exception while setting properties for bean =
- Entry found in SnmpNotifyFilterTable with profileName=
- Invalid value for trap parser definition:=
- Failed to authenticate the SecurityParameters for user=
- Error : Value should be entered in Editor=
- No Columns Present in this ResultSet=
- Parse Error: Incorrect HeaderData=
- Error Message=
- Information=
- subID value should be less than 4294967295:=
- Loading MIBs from Compiled File.=
- Cannot plot graph for:=
- Unable to delete the entries :=
- Cannot connect to Database=
- Index Editor=
- AccessControlModel NOT Registered=
- 1.The keyword 'ACCESS' or 'MAX-ACCESS'may be missing. or n2. The keyword 'SEQUENCE OF' may be missing. or n3. The syntax with invalid subType construct.=
- Parsing Level For=
- Error in SnmpTable Bean=
- the value is not in range=
- ENTERPRISE=
- Report=
- REFERENCE=
- Max Xaxis-Val(sec's.)=
- Error Status: no error=
- ReLoading ..=
- Specific Type=
- cannot read file ... continuing anyway=
- Packet from:=
- In the DEFVAL construct, n1.The default value should be enclosed with curly brackets. n2. The default value should be within single quotes.=
- Error Reading File.=
- SNMP Version: Version 2=
- SNMP Version: Version 1=
- Error: Invalid Request for V1=
- USMUtils:encrypt:Invalid Algorithm Parameter :=
- Writer version :=
- Access:=
- Parse Error: Decoding trap_type.=
- Overwrite existing Compiled MIB Files=
- Table Index=
- Request Failed:=
- Node access=
- Should have resolved or atleast fixed import by now.=
- Not a valid date=
- Save MibBrowser Debug Messages As...=
- Time in months=
- Error loading Mib:=
- Error : No such Security Level=
- USMUserEntry : could not send a notInTimeWindow report PDU=
- Will read=
- Security Model with model number=
- Port is already in use :=
- Request timed out=
- Stop query in progress=
- Parent Object class :=
- TRAP-TYPE=
- ASSERT:Wrong type:=
- v2 Notification=
- all the OID=value pair mentioned below, then the trap is=
- Exception: SnmpDataAndTime: Not a valid year=
- cds file cannot be compiled=
- Error: IO Error=
- Error :No such Listener available=
- with version=
- Unable to find TransportConfigFile=
- FROM=
- ToolBar=
- No Root node is available=
- View Line graph=
- noAuth,noPriv=
- Priv Protocol=
- Failed set timeout :=
- Done=
- warmStart=
- Time in minutes=
- Save V3Tables in the Database=
- Funny results: Examine this case :=
- SnmpParameterPanel=
- Print Debug Messages...=
- SAS error message :=
- Node:=
- LocalPort=
- Invalid Radix=
- New parser ...=
- MIB not loaded or not a valid OID. Cannot find MIB node. OID:=
- Variables :=
- Create New Parser File from Parser List=
- Error in writing to output Stream :=
- Value of port should be a number=
- Access is -1. Verify why. A simple reason could be that this IS AN OBJECT-IDENTIFIER=
- Please enter the URL=
- NO_AUTH_NO_PRIV=
- port :=
- Load a MIB File=
- Choose a severity color=
- Message Version=
- Could not find the Specified Mib=
- Parse Error : Expected priv string=
- Enter the parser name=
- MalformedURLException occurred when trying to find resource=
- A resource unavailable error occurred.=
- Next=
- Aborting ...=
- Please enter the Username=
- Source=
- Error: Session Remote Host Unknown.=
- linkDown=
- Error:Agent Returned Empty Variable=
- TrapParser=
- SnmpEngineEntry not found=
- Remove=
- .. for node=
- Specfies the Network value for the trap=
- GetNext Request=
- Parse Header: Incorrect Paramdata=
- ObjectID=
- Remote File Dialog=
- Create Custom Parser File=
- Could not find SecurityProvider file=
- Error decoding Packet:=
- Illegal Argument Exception=
- at line=
- ColumnName :=
- Could not parse the .cmi File=
- Could not recognize syntax type:=
- No Parsers defined, You need to define atleast one parser.=
- USMUtils:getDigestImpl : Error:=
- Error. MIB node unavailable for OID.=
- Trap Parser Editor=
- TableItems:=
- Command=
- Loading Parser File=
- Exception:=
- Warning Message=
- Cannot bind to address:=
- MIB?=
- SeriousSettings=
- Cannot Listen on port :=
- Invalid format for:=
- Page=
- in DEFVAL=
- Text Files=
- LineGraphBean Error: cannot plot string value=
- Encode Error: Wrong SNMP Version:=
- Load Mib Dialog=
- Exception in encoding=
- OID=
- Exception: SnmpDataAndTime: Not a valid month=
- OID Not Specified=
- SYNTAX:=
- Cannot open file:=
- cmi file cannot be compiled=
- specified=
- Save File=
- Time:=
- Error initializing Security Provider:=
- Expecting MANDATORY-GROUPS or GROUP/OBJECT keyword=
- SNMP Table Settings=
- ASN1Parser:encrypt:Encryption Failed=
- Not a valid second=
- Failed. This is not the root of class iso..:=
- ASSERT:Invalid Status value=
- Missing MIB node or leaf node.=
- Exception during Internationalizing=
- No elements in varbind. Returning null=
- Exception occurred during Snmp EngineBoots deserialization=
- Is it indexed ?=
- Table OID should be specified=
- Parser file must have .parser extension=
- Entry found in SnmpNotifyFilterProfileTable with paramsName=
- Varbinds=
- OriginalTable=
- New=
- Encountered a reserved word=
- All=
- Show table rows of the next page=
- User Defined=
- Error : OidList not specified=
- SNMP Table=
- v2c=
- Open=
- Cannot plot the chosen variable:=
- The name of the Imported item should be n1. lowercase name or n2. uppercase name,if TEXTUAL-CONVENTION n3. SnmpConstructOrTypeName, which is the name of an SNMP type or construct defined in one of the SMI MIB modules;=
- threads of scheduler:=
- No GetBulk request in V1 .Sending GetNext request=
- Compiled File=
- . Verify code.=
- Level Name=
- Unable to execute query :=
- Parser Name=
- authKey length has to be=
- Exception occurred while modifying entry :=
- Error in sending response for INFORM_REQ PDU=
- View SNMP data table=
- Unknown Error in security level=
- Not a valid month=
- Error:Discovery Failed=
- Couldn't open stream for=
- Configuration of Trap Parsers=
- URL=
- Syntax=
- Reference :=
- Reading OBJECT_TYPE=
- Error in closing the socket :=
- Multi-Varbind=
- Object ID:=
- USMTable is null=
- Invalid data :=
- Max-Repetitions=
- data.length=
- An inconsistent value eror occurred.=
- The keyword 'SYNTAX' or 'SEQUENCE OF' may be missing.=
- Exception: SnmpDataAndTime: Not a valid deci second=
- Refresh=
- Auth Parameters=
- Node=
- not found in Table=
- File Not found :=
- Rows=
- Decode error=
- Cannot get column instances:=
- linkUp=
- Port(s) already in use=
- An error occurred while creating entries=
- No Of Column View=
- Column Node Details=
- The 'INDEX' or 'AUGMENTS' keyword was missing in the table row object type construct which contains the sequence as=
- view Graph for selected cell(s)=
- Current Directory=
- Trying to allocate a VERY BIG PDU=
- Exception while assigning data from SnmpProperties :Not a number=
- Exception while constructing message after receiving PDU. Dropping this PDU=
- Enterprise OID=
- Parse Error: Decoding reqid.=
- SNMP Trap PDU=
- Exception while forming help URL=
- Caught Exception:=
- Error : Timeout Value cannot be negative=
- Load MIB File=
- Snmp Version=
- Sent Type:=
- Error : Retries Value cannot be negative=
- Invalid SAS transport provider:=
- Could not create security table for COMMUNITY=
- Node status=
- Trap OID=
- Global View=
- Round Trip Delay:=
- Failure Object=
- Unexpected end of file while reading File:=
- Loading MIBs=
- The keyword 'OBJECTS' or 'STATUS' may be missing.=
- Error in parsing int=
- Syntax :=
- Html Files=
- port=
- Parser file not found :=
- Error Status:=
- Find in All=
- User Defined Levels=
- USMUtils:encrypt:Key Exception while encrypting:=
- Parser name Duplicates=
- Auth Protocol=
- Error Sending PDU.=
- OID Value List=
- Save V3Tables in the File=
- LOADPARSER=
- MatchCriteria=
- Number of :=
- DESCRIPTION=
- Enter the OID:value pair. If the received trapPDU contains =
- Invalid Tag=
- Priv Parameters=
- Enter the Database Parameters=
- enterpriseSpecific=
- Error: VariableBindings Index out of Range=
- Main Level=
- Scheduler:=
- Time sync failed=
- Not connected to sas=
- ++++++returning numbered oid :=
- Cancel=
- Target Host=
- Loading option set to Direct.=
- Maximum Size=
- Host=
- Parse Error : Expected engine id string=
- usmStatsUnknownUserNames=
- Null Byte Array=
- No suitable driver=
- Snmp Table=
- Add=
- usmStatsNotInTimeWindows=
- Do you want to really quit=
- Error Reading MIB File:=
- StartPolling=
- Node syntax not String type=
- Mib Description=
- The 'ASSIGNMENT' or 'DEFVAL' keyword may be missing.=
- LineGraphBean Error: cannot plot these values=
- Error : MIB node unavailable for OID.=
- Save V3 Settings to Database=
- In initTransportProvider=
- RequestID:=
- Error: Agent Returned Non-Numeric Value=
- Setting SAS transport provider to:=
- Error :DataType cannot be negative=
- Trap Port=
- The object identifier may start with ModuleName.(The module name should should start with uppercase letter.)=
- Error: Invalid Table OID=
- SNMP V2 Trap PDU=
- Retrieval Mode=
- Error encoding EventManager=
- Loading Parser File =
- Sending inform request for host=
- Parse Error: Decoding message id.=
- The=
- Error : Column Index cannot be negative=
- seconds=
- Enterprise :=
- Loading afresh..=
- Unable to find the resource=
- out of=
- Error: MIB node unavailable for OID.=
- Browse=
- IO Exception while retransmitting the PDU=
- Error: Agent Returned Empty Variable=
- Import Level=
- Snmp Port=
- Save MibBrowser Debug Results=
- Unable to decode PDU.=
- General Options=
- to host :=
- Not able to get the file=
- No Such Row Exists=
- SnmpEngineEntry not found for address=
- MIB File=
- Parse Error: Decoding agent_address.=
- Non Repeators=
- A commit failed error occurred.=
- This is not a TC strangely "+".. for object=
- properties file=
- General=
- Error parsing quoted filename :=
- The Enterprise name should start with lowercase letter or may start with Module name and should be separated with period (ModuleName.enterprisesName).=
- GetBulk Request=
- Invalid File Name=
- Parser Files=
- Checking if imports pending=
- Imports Error=
- Confirm Exit=
- Reference:=
- Parser File=
- Save Debug Messages As...=
- Next 10 octets :=
- Could not find Access Control Provider file=
- Found module Name in=
- Error in sending :=
- Compiled Mib=
- The subID construct the number should enclosed with brackets.=
- USMUserEntry : could not send a unknownUserNames report PDU=
- Open Help=
- Cannot listen on the specified port :=
- Specifies the Message associated with this Trap=
- Parser Name duplication=
- Del=
- Print MibBrowser Debug Results=
- Performing recovery..=
- Entries found in SnmpTargetAddrTable with tag=
- Security Model=
- usmStatsWrongDigests=
- Set Request=
- Number of TCs to be added :=
- Not a valid year=
- Log Polled Values?=
- USMUserEntry : could not send a wrongDigests report PDU=
- SnmpBitString: Size less than array limits.=
- Save SNMP Decoder Messages As...=
- Exception in parsing OCTET STRING defval:=
- Reader version :=
- Error communicating with SAS Server.=
- Expecting the right brace.=
- did not stop in=
- OutPut Event Parameters=
- has not at all registered=
- Error sending set request:=
- Poll.Val=
- No data available in this sub-tree=
- MacroType=
- Sending inform request to host=
- Split Columns ?=
- did not stop properly:=
- Found node=
- Connected to remote socket on applet host.=
- Remote address is not specified.=
- Stream Corrupted=
- Start Polling the Table Values=
- CriticalSettings=
- Message ID:=
- Object ID=
- UserName=
- from=
- SecurityModel already Registered=
- Security Model Table Object already created=
- Parse Error: Decoding message SecurityModel.=
- Modify=
- Warning=
- Get Request=
- Couldn't find file in search path specified:=
- All Files=
- Notification filtering has not been enabled in SnmpAPI=
- Error in get request to=
- Inform=
- Error: Agent Returned Empty Varbind(s)=
- Recent=
- Recently Loaded Mibs=
- 1. In case of OBJECT construct 'SYNTAX' , 'WRITE-SYNTAX', 'MIN-ACCESS' or 'DESCRIPTION' may be missing. n2. In case of GROUP construct keyword DESCRIPTION may be missing.=
- Response had a non-zero errorStatus value :=
- SNMP ASN1Error encountered due to Illegal SNMP packet received=
- Error in writing to Stream :=
- Do you want to unload=
- Selected user is=
- Value:=
- Want to save the created parser file=
- Reference=
- object variables=
- Received Time:=
- A wrong length error occurred.=
- Error in SnmpPoller Bean :=
- V3 Parameters=
- Generic Type=
- Error: OID not a leaf node.=
- Settings=
- Get=
- The output parameters shown on the Trap Table for filtered=
- SNMP Report PDU=
- Error : No such column Index=
- Cannot plot string values:=
- Save MibBrowser Results=
- Sent Time:=
- V3 Options=
- Modify Entry=
- Exit MibBrowser=
- from 0 to 4294967295.n2. The object idenitifier which should start with lowercase letter.n3.==
- Show All Points=
- imported file name=
- SNMPV3 Authentication failure occurred=
- Exception :=
- finding node=
- Line=Graph=
- Enter agent name=
- I don't know what occurred.=
- Applet not supported=
- Introspection Error :=
- Couldn't resolve these MibNodes :=
- Error in init method=
- Error: Invalid Non-repeaters Value=
- Wrong notifyType for host=
- Specifies the category value for this trap=
- Exception scheduling task in scheduler:=
- Error : No such index exists=
- Mod=
- Dropping .... Not a Trap PDU=
- Inform request timed out for host=
- AUTH_NO_PRIV=
- ObjectID :=
- Couldn't use the system look and feel:=
- The variable is read only=
- The keyword 'INDEX' or 'AUGMENTS' may be missing.=
- 1. The subOID may be missing. n2. The OID value reference should start with lowercase letter. n3. The OID value reference may start with modulename and should be seperated with . . (The module name should always start with uppercase letter.)=
- Invalid Protocol. Use IP only.=
- CustomizeLevel=
- MibNode should be selected=
- Finds the next occurance of the node name in the tree=
- Module name not found in=
- Invalid Protocol. Use IP or IPX only.=
- Range: 1000 sec.=
- Error in response=
- active threads stopped in=
- dataLength=
- Security Level=
- Unknown Host=
- Match case=
- Load MIBs From Compiled File=
- Match Criteria=
- Index=
- is missing.=
- Remote Host:=
- Packet msgID:=
- Non Repeaters=
- Error: Invalid Context ID=
- Port Number Should be a positive integer=
- Error : Polling interval cannot be negative=
- Select any of the entry in the table to delete=
- Write Community=
- USMUserEntry : could not send a Discovery reply=
- Loading MIBs directly.=
- Discovery succeeded for user :=
- Invalid Port Number=
- Errored Object ID:=
- Node data printin.1..=
- Failed search for node:=
- IndexEditor=
- Invalid Bitsting: Cannot encode=
- Unable to write to database :=
- Auth,Priv=
- Select the Parser to be modified=
- Incorrect VarBindList=
- Error : Creating variable.=
- Error in getnext request to=
- GetBulk=
- Origin=
- Mibs has been loaded from other Database .n Do you want to change to this database.n All the Mibs already loaded will be unloaded=
- Aborting at line :=
- cds read in :=
- active threads in the control=
- Error loading MIB:=
- UserName:=
- No Description for the item selected=
- Error writing to:=
- Date=
- v3=
- Set Parser Level=
- v2=
- v1=
- to=
- Polling Interval (sec.)=
- Do you want to change to this Mode?=
- Cannot modify the user entry=
- encountered in=
- Trap Type:=
- Error :No such DataType=
- MibListDialog=
- Save MibBrowser Results As...=
- Snmp_Version3=
- Snmp_Version1=
- Mib File List=
- Unloading MibModules Failed:=
- Invalid TrapPort Parameter:=
- Error:=
- Time in hours=
- TimeStamp=
- Sub-Id :=
- Invalid ObjectID=
- Sending PDU:=
- Timed out: Resent to=
- Add Agent and port Criteria.=
- Error = Invalid port number :=
- UnLoad MIB Module(s)=
- Time Sync failed for user=
- Confirm Unload=
- Range: 300 sec.=
- Encryption Failed=
- is corrupted=
- Help=
- Recently Loaded Mibs =
- Invalid ColumnName:=
- No error=
- Enter Agent Name=
- Find What=
- authenticationFailure=
- exit:=
- SNMP Inform Request Request PDU=
- View=
- Value=
- MibBrowser Applet does not saven MibBrowser results into files=
- Module Name :=
- View MibNode details=
- Driver class not found:=
- Error getting method to encode=
- Placed PDU in request queue.=
- Error : Illegal Argument(s)=
- Enter the standard Match Criteria=
- No Error code registered=
- Error:Time Synchronization Failed=
- Confirm Message=
- Find Next=
- Read in trap enterprise :=
- Row Addition Editor=
- Error creating SnmpIpAddress : invalid byte arg.=
- Error in sending pdu :=
- Show Absolute Counters=
- Loaded MibModules=
- No Valid row specified=
- Please enter a MibNode and press Find Next=
- There is no such object in this MIB.=
- Parser File List=
- Result Display=
- ASN1Parser:encrypt:Encryption Failed:=
- User should use unknown SAS type as userType (> SAS_VALID_TYPES)=
- Set MIB Browser Parameters=
- Trap Parser=
- Count of Modules:=
- Traps=
- SNMP Set Request PDU=
- Warning: Unable to load the=
- Cannot connect to MIB database.=
- Error: SNMP not initialized=
- on=
- ASSERT:Invalid type=
- SysUpTime=
- Parse Error: Decoding specific_type.=
- About...=
- Error: Invalid generic type for trap=
- TimeSynchronization failed for user :=
- Enter the Language and Country name for Locale=
- Specifies the Specific Type value of a trap with Generic Type 6. Enabled only when Generic type values is 6.=
- Unable to create Statement: Database access error=
- Graph Type=
- No. of kids :=
- A wrong type error occurred=
- Error while registering securityProvider=
- Received Packet=
- Host Name is not Specified=
- Invalid Retries Parameter:=
- Name=
- session.send: IO error while sending=
- Transport provider not configured=
- Severity=
- Specific Type=
- Invalid Byte Array=
- 1. The identifier should not start with uppercase letter orn2. In case of TEXTUAL-CONVENTION/SEQUENCE construct the keyword ASSIGNMENT (::=
- Loading MIB=
- Could not create security table=
- SNMP Get Next Request PDU=
- Scale value should be an integer=
- Cannot read file :=
- Parse Auth: Incorrect VarBind=
- Setting transport provider to default.=
- Unexpected termination in OID Syntax parse=
- usmStatsUnsupportedSecurityLevel=
- Port 0 cannot be used for receiving traps.=
- Set Value=
- This failure object is used for correlation of events for a given Network element. Use this field to group events based on the Network element generating the Trap=
- Node OID:=
- Warning :=
- MibNode not available for the oid :=
- This is not a TC strangely .. for object=
- Authenticate v3 Traps=
- Port=
- Ipaddress can't be represented in binary format in DEFVAL clause=
- Error : OID not a leaf node.=
- v1 Trap=
- Add Entry=
- USMUtils:encrypt:Bad padding:=
- Database Settings=
- Main File=
- Error : AuthProtocol cannot be negative=
- Specific Type:=
- Error in closing error Stream :=
- Choose the file you want to save in the Webserver=
- New Parsing Criteria will not take effect,=
- Critical error in adding child=
- Collapse the Tree=
- Send Error:=
- The MACRO definition ( OBJECT-TYPE,TRAP-TYPE, ...) may be missing. or The identifier may be invalid.=
- Set the module Name for=
- V3DBParams=
- Couldn't mask into transportAddress=
- Match Entire OID=
- Error : Index=
- Click here to sort column=
- Error in Reading the File:=
- egpNeighborLoss=
- is not defined in the MIB :=
- Parse Error: Decoding errstat.=
- Brings up a dialog for entering traps from a File or Mib=
- Assuming this is a root element such as iso.. :=
- JDBCParams=
- Macro Type is=
- Get Response=
- Specifies the node that originated the trap=
- V3 Settings=
- Net Mask=
- Output Event=
- Errindex:=
- Read in trap description :=
- Error in label=
- Error : Security Level cannot be negative=
- RELEASE :=
- Value :=
- Invalid format for :=
- Error Reading=
- Incorrect number of Index values. OID:=
- HelpURL=
- Exception occurred during deserialization=
- Find Node=
- No Host Specified=
- Print MibBrowser Decoder Results=
- Timed out=
- HostName should be entered=
- Inform Request=
- Root node is=
- Sent getnext request to=
- Provides a space for you to type the search string=
- The field=
- Invalid X-axis Scale value:=
- Parse Header: Incorrect Encrypted Scoped PDU Header=
- No of Columns/Request=
- Operations=
- Invalid Index=
- Time in Years=
- File URL=
- No Levels Defined.=
- LOADMIB=
- Unable to get entry from the database :=
- Parse Header: Incorrect Context Name=
- Load Mib File=
- all the OID:value pair mentioned below, then the trap is =
- SNMP Get Response PDU=
- Password=
- Error: Connecting to Applet Host :=
- Delete=
- for=
- Clear Selection=
- Packet ReqID:=
- USMUserEntry not found for this user. TimeSynchronization failure could have occurred=
- Updating syntax for=
- Restore Defaults=
- Please check the classpath and try again.=
- could not create the table=
- Closes this dialog=
- ASN1Parser:decrypt:Decryption error=
- Transport provider not configured.=
- Close=
- The output parameters shown on the Trap Table for filtered =
- No mibs loaded=
- Engine Boots=
- Polling Interval (sec's.)=
- UnknownHostException :=
- Connect=
- invalid radix: specify hex/bin=
- Access=
- Invalid Hex String:=
- Non Numeric value:=
- Updated List=
- Files=
- Permission Denied=
- while creating SnmpVar=
- Specify the FileName in the ParserFile TextField=
- Exception: SnmpDataAndTime: Not a valid minute=
- Find=
- ColumnIndex=
- Exception in parsing defval:=
- ClassCastException while retriving address=
- Error cloning in updateSyntax of MibTC :=
- import mib=
- Error : Invalid Column OID=
- Searches for the specified node name matching the case entered=
- Specifies the Enterprise Object Id corresponding to this trap=
- Error: OID Not Specified=
- Description:=
- construct the identifier should start with lowercase character.=
- Error : Table OID not specified=
- USMUserEntry : could not send a timeSync reply=
- HOST=
- SnmpTrapOID=
- File:=
- The ASSIGNMENT keyword may be missing.=
- TimeSynchronization succeeded for user :=
- Parsing Level=
- Parse Error: unrecognized SNMP message=
- Enterprise:=
- No ObjectID specified.=
- Skipped=
- Can't find node for this String index in vector :=
- Colour=
- File=
- Exception: SnmpDataAndTime: Not a valid second=
- SNMPV3 Error in Response.=
- Get Bulk SNMP data=
- Set=
- Could not create security table for USM=
- Show Absolute Time?=
- could not create the entry=
- Enterprise OID=
- Driver Name=
- A no access error occurred=
- USMUtils:encrypt:Illegal Block Size:=
- This is a end of Mib View.=
- There is no serialized object=
- Show Details=
- File name invalid=
- New parser =
- Range: 600 sec.=
- Stack size :=
- of the schedulers stopped=
- Access :=
- Not a valid deci second=
- view column node details=
- Module name should start with the uppercase letter.(and usually contains no lowercase letters).=
- Was expecting a ModuleName and that should be in upper case or atleast in proper case=
- Refresh the table=
- Request ID:=
- Hex PDU=
- Load from file=
- Could not create ACM table for VACM=
- Direct=
- Go To Sibling Node=
- Invalid Binary Value=
- Remote Address:=
- Bar Chart=
- IO error message being resent=
- Line:=
- Load=
- Defval=
- Error : Auth Protocol cannot be negative=
- edit the header name for selected column=
- Unknown Error=
- Exit=
- New Name=
- Not Listening for Traps=
- Authenticate v1/v2c traps (Community)=
- Authenticate v3 Trap=
- Listening for Traps=
- Optional- Traps will be received only for the specfied=
- Disable Error Dialog=
- View from=
- Enter the OID:value pair. If the received trapPDU contains=
- all the OID:value pair mentioned below, then the trap is=
- MibDescriptionUI=
- Length of SNMP DATA:=
- SystemUpTime value=
- USM Entry is already added to USM Table=
- Invalid authProtocol or authPassword=
- Decryption Error=
- Invalid EngineID=
- Invalid UserName=
- UnSupported Security Level=
- ErrorDialog=
- Cannot Modify No Auth, No Priv Entry=
- Please select one v3 Table entry=
- Cannot Connect to SNMP V3 Database=
- There are no entries in the V3 Table to delete=
- Please select atleast one Entry from the V3 Table to delete=
- Cannot connect to database=
- Connection cannot be established=
- Please enter a valid port number=
- NoAuth,NoPriv=
- Auth,NoPriv=
- AuthPassword should be specified if authentication is used=
- Port should be specified=
- Username should be specified=
- Host should be specified=
- PrivPassword should be specified if privacy is used=
- Set EngineID For Adding V3 entry=
- Engine ID=
- Invalid Engine ID=
- When Selected the EngineID textbox will be enabled while adding the V3 Entry, enabling user to add engineID as required.=
- UserName may be wrong=
- authProtocol or authPassword may be wrong=
- PrivPassword may be wrong=
- Network Mask Address is not a valid Mask Address=
- Please add or select a v3 user entry=